Description
ADR classification: 1.4S, IGNITERS, UN0454
Category: P1
Packing:
Length of wires | 0,3 m | 0,5m | 1 m | 2 m | 3 m | 4 m | 5 m |
Packing pcs/CTN | 2400 | 1200 | 960 | 600 | 360 | 320 | 240 |
Brutto kg | 7,5 | 6,3 | 7,3 | 8,8 | 8,1 | 8,8 | 8,9 |
Netto kg | 6 | 4,8 | 6,8 | 8,3 | 7,6 | 8,3 | 8,4 |
NEC kg | 0,031 | 0,016 | 0,012 | 0,008 | 0,005 | 0,004 | 0,003 |
Purchase condition: wholesale purchase only
Technical parameters of Electric igniters EPG-N
Instructions for use
For the initiation of electric igniters, it is possible to use a suitable firing system or a DC source capable of firing with a sufficiently large current pulse. For low-resistance electric igniters EMP-NO-A1/A2, an ignition current of 1A (4ms pulse) is required.
Always check the wiring for correctness before firing. The maximum number of electric igniters that can be connected in series is 10. Check the correct wiring of the electrical circuit with a current-limited tester up to 20mA.
In case the electrical circuit is not closed, re-measure the electrical resistance of the electric igniters individually. The maximum electrical resistance for a low-resistance electric igniter EMP-NO-A1/A2 is 2.4 Ω. The resistance should be measured with an ohmmeter that has a current limitation of a maximum of 20mA.
Protect against stray currents and static electricity. Avoid high temperatures, friction, and shocks during transportation. Avoid using and operating during thunderstorms. Do not use near high-frequency transmitters or high-voltage lines.
The products must be stored in their original packaging in closed, dry, unheated, brick-walled warehouses with natural ventilation. The storage temperature range is between 0°C to +40°C, RH ≤ 80.
Disposal of products at the end of their life cycle must be carried out under generally binding EU regulations and international agreements. Disposal of hazardous waste must be carried out by a specialized certified company following the relevant standards and regulations.
Signal Word: Warning
Hazard Statement H204: Fire or projection hazard.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P250 Do not subject to grinding/shock/friction. P280 Wear protective gloves/protective clothing/eye protection/face protection. P370+P380 In case of fire: Evacuate area. P372 Explosion risk. P373 DO NOT fight fire when fire reaches explosives. P401 Store in accordance with national laws. P501 Dispose of contents/container in accordance with national laws.